| Sign In | Join Free | My insurersguide.com | 
 | 
Brand Name : CONSNANT
Model Number : CNM330-180K
Certification : CE, ISO9001, ISO14001
Place of Origin : Shenzhen, China
MOQ : 1 Unit
Price : Negotiable
Payment Terms : T/T, L/C, Western Union
Supply Ability : 500 pieces per month
Delivery Time : 20days after receiving 30% deposit
Packaging Details : Export Standard Package
Power Factor : 0.99
Frequency : 50/60
Norminal Voltage : 380/400/415VAC
THDi : <3%
Display : LCD/LED
Phase : Three phase
Output Capacity : Large Type
Cabinet Color : Black/white
High Efficiency Modular UPS System Parallel Redundancy Online
30 - 180KVA
 
 
 CNM330 series is modular online UPS for sensitive equipment. The single cabinet power rating covers from 10KVA to 300KVA which delivers the best of combination of reliability, hot-swappable and flexibility. With the latest IGBT three-level technology and DSP control, CNM330 achieves a high input power factor, low THDi Modular design with N+X redundancy and online hot swapping ,easy to expand the capacity Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance and reduced size
 
  
Application:
 Application IDC(Internet Data Center)
Computing center
ISP (Internet Service Provider )
Telecom , Finance, bank and securities , Tax
Hospital system , industrial automation
Precision equipment, etc.
 Features:
■ Superior energy saving :
 Efficiency > 96% at 50%-75% rated load, and > 95% at 25% rated load; Input PF > 0.99,input THDi<3%
 ■ Easy-to-install:
 Top or bottom cabling, no need of input cabling cabinet.
 ■ Easy-to-maintain:
 Full front access, UPS, failed part can be replaced shortly
 ■ Easy-to-modify:
 The number of batter y cells can be configured flexibly, so the original batteries can be used when modifying the legacy
 system; moreover, the battery cell can be replaced in time when it fails without interrupting the normal operation of UPS.
 ■ Extra large LCD that can display 12 language (Chinese ,English ,Russian, French ,Spanish and so on).
 ■ Provide large LCD touch screen (optional)
 ■ Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A
 ■ Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance
 ■ Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion
 without centralized bypass cabinet
 ■ Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges
 ■ Intelligent battery management maintains battery automatically to prolong the battery life
 ■ The machine system for modular structure, consists of 1 to 10 module's biggest single module to 30kw
 ■ UPS power module supporting hot swappable, capacity upgrade extremely simple.
 ■ Super ability for overload and short circuit, ensure the system stability and safety under the limit state of system
 Technical Specifications:
| Model | CNM330 20-300KVA | |
| Capacity | 20-300KVA | |
| Main Input | ||
| Input Voltage | 380V/400V/415V | |
| Input Frequency Range | 50/60Hz | |
| Power Factor | Full load>0.99 ,Half load >0.98 | |
| THDi | THDi<3% | |
| Input Power Soft-start Function | 5-30s settable | |
| Input Voltage Ranges | 228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40% | |
| Frequency Range | 40-70HZ | |
| Battery | ||
| Battery Voltage | ±240VDC(Default),12V Battery 30~40pcs can be choose | |
| Charge Voltage Accuracy | ±1% | |
| Bypass | ||
| Bypass Input Voltage | 380/400/415VAC 3-phase 4-wire | |
| Voltage Range | Default value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software | |
| Overload Capacity | Long term at 135% rated load ,150%<load<180% more than 10 min, load>1000% 100ms | |
| Output | ||
| Inverter Output Voltage | 380/400/415VAC 3-phase 4-wire | |
| Voltage Accuracy | ±0.5% ( balanced load ) , ±1% ( unbalanced load ) | |
| THDV | THDV<1% (linear load) , THDV<3% (nonlinear load) | |
| Power Factor | 0.9 | |
| Three Phase Angle Accuracy | 120°± 0.5° | |
| Current Crest Ratio | 3:1 | |
| Overload Capacity | 110%1h,125%10mins,150%1mins,>150%200ms | |
| Transfer Time | 0ms,15ms (Eco Mode) | |
| System | ||
| Frequency | 50Hz/60Hz (Settable) | |
| Mains Synchronization Range | ±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz | |
| Protection Level | IP20 | |
| Communication Ports | RS232,RS485,dry contact, SNMP card, EPO, generator port | |
| System efficiency | >96% at load above 50%, >95% at load above 25% | |
| Operation Temperature | 0-40ºC | |
| Storage Temperature | -25ºC~70ºC ( without battery) | |
| Humidity | 0-95% (no-condensing) | |
| Noise(dB) | 55-62dB,Adjusted with load | |
| Weight | module:PM20 | 20KVA power module : 35KG | 
| module:PM30 | 30KVA power module : 35KG | |
| module:PM40 | 40KVA power module : 35KG | |
| Dimension (W x D x H)mm | 3 module cabinet | 600X900X1135 | 
| 5 module cabinet(5 battery cabinet option) | 600X1100X2070/ | |
| 6 module cabinet | 600X900X1535 | |
| 10 module cabinet | 900X900X2080 | |
| power module | 440X650X132(3U)(10KVA/20KVA/30KVA) | |
 (Optional South America 208V must be derating use)
CONSNANT Modular UPS in hospital

|   | 
| High Efficiency Online Modular UPS System Three Phase Input Voltage 380V / 400V / 415V Images | 
 Pure Sine Wave Modular UPS System 180 KVA High Output Load Three Phase
                                                                                    
                        
                        
                        
                                                            Pure Sine Wave Modular UPS System 180 KVA High Output Load Three Phase
                                                    
                        
                     Easy Maintenance Modular UPS System 300 KVA Large Data Record High Overload
                                                                                    
                        
                        
                        
                                                            Easy Maintenance Modular UPS System 300 KVA Large Data Record High Overload
                                                    
                        
                     180 KVA Online Modular UPS System High Efficiency Parallel Redundant
                                                                                    
                        
                        
                        
                                                            180 KVA Online Modular UPS System High Efficiency Parallel Redundant
                                                    
                        
                     Three Phase High Capacity UPS System Parallel Redundancy Online 30 - 180KVA
                                                                                    
                        
                        
                        
                                                            Three Phase High Capacity UPS System Parallel Redundancy Online 30 - 180KVA
                                                    
                        
                     Self - Diagnosis Modular UPS System Unbalance Load With Comprehensive Protection
                                                                                    
                        
                        
                        
                                                            Self - Diagnosis Modular UPS System Unbalance Load With Comprehensive Protection
                                                    
                        
                     Online N + X Redundancy Data Center Battery Backup System High Stability 50 /
                                                                                    
                        
                        
                        
                                                            Online N + X Redundancy Data Center Battery Backup System High Stability 50 /
                                                    
                        
                     300KVA Modular UPS System High Overload Capacity Large Type Power Backup
                                                                                    
                        
                        
                        
                                                            300KVA Modular UPS System High Overload Capacity Large Type Power Backup
                                                    
                        
                     Smart Control Uninterruptible Power Supplies Industrial Automatic Demand
                                                                                    
                        
                        
                        
                                                            Smart Control Uninterruptible Power Supplies Industrial Automatic Demand
                                                    
                        
                     Automatic Calibratoin Large UPS Systems Front Access Easy - To - Modify
                                                                                    
                        
                        
                        
                                                            Automatic Calibratoin Large UPS Systems Front Access Easy - To - Modify
                                                    
                        
                     Large Data 3 Phase UPS System Hot - Swap Battery Cabinet N + X Prallel Redundant
                                                                                    
                        
                        
                        
                                                            Large Data 3 Phase UPS System Hot - Swap Battery Cabinet N + X Prallel Redundant